Brocade Communications Systems 5300 Service Manual Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
Brocade 5300 Hardware Reference Manual 29
58-1000858-02
Environmental requirements
A
Environmental requirements
Table 7 lists the acceptable environmental ranges for both operating and nonoperating (such as
during transportation or storage) conditions.
General specifications
Table 8 lists the general specifications for the Brocade 5300.
Nominal system DC power consumption 260 Watts
Input voltage 85-264 VAC
Input line frequency 47-63HZ
BTU rating 1313 BTU/hr
Inrush current Maximum of 38A for period of 10-150mS
Input line protection Both AC lines are fused
TABLE 6 Power Supply Specifications
Specification Value
TABLE 7 Environmental requirements
Condition Acceptable during operation Acceptable During Non-Operation
Ambient
Temperature
0º to 40º C
32º to 104º F
-25º to 70º C
-13º to 158º F
Humidity 10% to 85% RH non-condensing, at
40º C (104º F), with maximum gradient of 10%
per hour
10% to 90% RH non-condensing, at 70º C
(158º F)
Altitude 0 to 3 km (10,000 feet) above sea level 0 to 12 km (40,000 feet) above sea level
Shock 20 G, 6 ms, half-sine wave 33 G, 11 ms, 3/eg Axis
Vibration 0.5 G, 5-500 Hz 2.0 G, 5-500 Hz
Air flow High speed 9000 RPM 102 CMH (60 CFM)
Low speed 6000 RPM 74.8 CMH (44 CFM)
None required.
TABLE 8 General specifications
Specification Description
Configurable port types F_Port, FL_Port, E_Port, EX_Port, and M_Port
System architecture Nonblocking shared-memory switch
System processor Freescale MPC8548 x 1.3GHz
ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and Signalling Interface standard)
Modes of operation Fibre Channel Class 2 and Class 3
Fabric initialization Complies with FC-SW-3 Rev. 6.6
FC-IP (IP-over-Fibre Channel) Complies with FC-IP 2.3 of FCA profile
Page view 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 51 52

Comments to this Manuals

No comments