Power supplies Two internal, redundant, eld-replaceable, load-sharing AC power supplies
Power inlet C13
Input voltage 85 to 256 VAC nominal
Input line frequency 47 to 63 Hz
Inrush current 50 amps max
Maximum current 3.5 amps max (24-port switch); 7 amps max (60-port switch)
Maximum power consumption 132 watts (24-port switch); 330 watts (60-port switch)
Safety Compliance
• Bi-Nat UL/CSA 60950-1 Second Edition
• CAN/CSA-C22.2 No. 60950-1 Second Edition
• EN 60950-1 Second Edition
• IEC 60950-1 Second Edition
• GB4943-2001 and GB9254-1998
• CNS 14336(94)
EMC
• FCC Class A
• ICES A
• VCCI-Class A
• CE
• C
• BSMI
• GOST
• KC Class A
• CCC
Immunity
• ANSI C63.4
• ICES-003 Class A
• CISPR22 and JEIDA (Harmonics)
• EN55022 Class A and EN55024
• CISPR22
• AS/NZS CISPR22
• CNS 13438(95)
• 51318.22-99 and 51318.24-99
• KN22 and KN24
• GB17625.1-2003
Environmental Regulatory Compliance
• RoHS-6 (with lead exemption) Directive 2002/95/EC
Standards Compliance
The Brocade VDX 6720 products conform to the following Ethernet standards:
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree
• IEEE 802.1w Rapid reconguration of Spanning Tree Protocol
• IEEE 802.3ad Link Aggregation with LACP
• IEEE 802.3ae 10G Ethernet
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1p Class of Service Prioritization and Tagging
• IEEE 802.1v VLAN Classication by Protocol and Port
• IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
• IEEE 802.3x Flow Control (Pause Frames)
• IEEE 802.3ab 1000BASE-T
• IEEE 802.3z 1000BASE-X
The following draft versions of the Data Center Bridging (DCB) and Fibre Channel over Ethernet (FCoE) standards
are also supported on the Brocade VDX 6720:
• IEEE 802.1Qbb Priority-based Flow Control
• IEEE 802.1Qaz Enhanced Transmission Selection
• IEEE 802.1 DCB Capability Exchange Protocol (Proposed under the DCB Task Group of IEEE 802.1 Working Group)
• FC-BB-5 FCoE (Rev 2.0)