Brocade Communications Systems StorageWorks 4/32B - SAN Switch Service Manual

Browse online or download Service Manual for Network switches Brocade Communications Systems StorageWorks 4/32B - SAN Switch. Brocade Communications Systems StorageWorks 4/32B - SAN Switch Technical data User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
HP StorageWorks Fabric OS 5.3.0c
release notes
Part number: AA-RWEYG-TE
S
eventh edition: November 2007
Page view 0
1 2 3 4 5 6 ... 25 26

Summary of Contents

Page 1 - Part number: AA-RWEYG-TE

HP StorageWorks Fabric OS 5.3.0crelease notesPart number: AA-RWEYG-TESeventh edition: November 2007

Page 2

FICON supportWith release 5.2.0 and later, the Switch Connection Control high integrityrequirement for cascading FICON is available in the standard ba

Page 3

FC4–48 port Blade forthe 4/256 SAN Director• The HP StorageWorks 4/48 SAN Director Blade requires a minimum of FabricOS 5.2.0a. Do not insert the FC4–

Page 4

Firmware upgrade/downgrade• When upgrading from Fabric OS 5.1.0x to 5.2.0x or 5.3.0x, if two or moreinter-fabric links (IFLs) connect to an edge fabri

Page 5 - Access Gateway support

HAIf there is an already segmented port and backbone devices are exported toan edge fabric, a build fabric/fabric reconfiguration can occur after runni

Page 6 - Security

FCIP• Frame drops observed on FCIP slow links:• The frame drops occur when the FCI P tunnel bandwidth is set to 10 Base-T(10Mbp s) , E1 (1.048M bps )

Page 7 - Prerequisites

Zoning considerationswith FC4–48 BladeB-Series switches running pre-5.2.0 firmware do not accept zone databases withDomain, Port Index, references to p

Page 8

Faulty SFPsExternal port with a faulty SFP will be disabled, then enabled once good SFP isinserted. However, port will still show as fault y even thou

Page 9 - Important notes

• Provides ability to clear 400 MP Router or B -Series MP Router Blade GE por t Error counters usingportStatsClear CLI command.Fabric OS 5.3.0 fixesTab

Page 10

User was able to configure isns client via isnsccfg to communicatewith isns server through a port on FR4-18i, but this will not work (norshould it).Fix

Page 11

Process login drop due to devices in different edge fabrics with samenode WWN. Applies to 4/256 with FCR-18i Blade, and 400 MPRouter. Routers may not

Page 12

Legal and notice information© Copyright 2007 Hewlett-Packard Development Company, L.P.© Copyright 2007 Brocade Communications Systems, IncorporatedCon

Page 13

Web Tools incorrectly returns “Directory change failed” errormessage rather than “file path provided is not valid” error messagewhen config upload fail

Page 14

Error messages from ACL configuration through SMI are too genericand don’t contain sufficient information to debug the problem.Fixed per Fabric OS 5.3.0

Page 15

During stress testing, a signifi cant delay in trafficcomingbackfrom a Fibre Channel Router (FCR) failure in fully redundant SANconfiguration was seen, a

Page 16

Vulnerabilities reported about open SSL VU#386964 & VU#547300.For VU#547300:OpenSSL SSL_get_shared_ciphers() vulnerable tobuffer overflow. For VU#3

Page 17 - Fabric OS 5.3.0 fixes

During iSCSI 1024 session stress testing, one port lost multiplesessions. Even though switchshow –iscsi showed less than 64sessions, iSCSI initiator w

Page 18

Fabric OS 5.3.0bfixesTable 5 lists defects closed in the Fabric OS 5.3.0b firmware release.Table 5 Fabric OS 5.3.0b closed defectsClosed defect summar y

Page 19

When FRU in a 4/256 Director is inserted/removed afruHistoryTrap should be generated, but is not.Fixed in Fabric OS 5.3.0c. Notethat fruStatusChangeTr

Page 20

Version5.3.0cEffective dateNovember 2007DescriptionFabric OS 5.3.0c is a patch release that contains fixes since the release of Fabric OS 5.3.0b. There

Page 21

Support for embedded switch modelsThe B-Series embedded switches have transitioned from supporting the Fabric OS 5.0.5 stream only, tooperating withFa

Page 22

• Access Gateway mode support on the H P StorageWorks 4 /16 SAN Switch (not supported on the4/8 SAN Switch)• Access Gateway enhancements:• Web Tools s

Page 23

requiring a domain and the associated fabric rebuild traffic that is prevalent when switches are poweredon, or added, or removed from a fabric.Refer to

Page 24 - Fabric OS 5.3.0a fixes

• DH-CHAP now supported for authentication of HBAs and end-devices in addition to switches• Additional password security options• LockoutofAdminuserst

Page 25 - Fabric OS 5.3.0c fixes

Table 1 Current supported Fabric OS versionsModel Earliest compatible versionRecommended versionHP StorageWorks 1 Gb Switch2.6.2c2.6.2d1HP StorageWork

Page 26

CAUTION:Install port blades like the HP StorageWorks 4/48 SAN Director Blade (FC4–48) only after upgradingto Fabric OS 5.2 . 0a or later.HP does not s

Comments to this Manuals

No comments