Brocade Communications Systems StorageWorks 4400 - Enterprise Virtual Array User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 38
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6
Software and hardware configuration
The following software and hardware components are used in this case study.
Software
VMware ESX server 3.5 U4
VMware vCenter 2.5 U4
VMware vCenter Site Recovery Manager 1.0 U1
HP Site Recovery Adapter for EVA 1.01
HP StorageWorks Command View EVA 8.0.1 or 9.1
Hardware
HP StorageWorks Enterprise Virtual Array, configured with:
o HP Fibre Channel (FC) Drives
o HP StorageWorks Continuous Access
o HP StorageWorks Business Copy
HP ProLiant BL480c and BL460c Servers
Brocade 4/24 Storage Area Network (SAN) Switch for HP c-Class BladeSystem
Cisco Catalyst Blade Switch 3020 for HP c-Class BladeSystem
Configuration details
VMware vCenter Server setup
Set up vCenter Server at each site
Create a single data center in each instance of vCenter Server
Add the local hosts to this data center
Basic VMware ESX Server installation
Follow your best practices for installing and configuring VMware Infrastructure 3. The ESX host can either
boot from local disks or from the SAN.
SAN switch zoning
Configure zoning in a way that all ESX servers for a given data center see only the local EVA. When
zoning is properly configured, ESX servers (esx11, esx12) in Data Center A have access to the local
storage (EVA 1) in Data Center A, and ESX servers (esx21, esx22) in Data Center B have access to the
local storage (EVA 2) in Data Center B.
Just as you would do in other environments, follow the SAN best practices. HP implements a best practice to
create separate single initiator/single target zones. (For example, limit the creation of two zones per ESX
Cluster in each fabric, as shown in Figure 2). This configuration provides a shared SAN environment in
which the FC switch from Data Center A and Data Center B are merged through inter-switch links (ISL) into
one SAN. For more information about zoning and SAN design considerations, see the HP SAN design
reference guide.
Page view 5