53-1001253-0109 June 09®Brocade AdaptersTroubleshooting GuideSupporting CNA Models BR-1010, BR-1020Supporting HBA Models BR-815, BR-825, BR-415, BR-42

Page 2 - Document History

x Brocade Adapters Troubleshooting Guide53-1001253-01Supported CNA hardware and softwareThis section describes adapter hardware and software support.

Page 3 - Contents

82 Brocade Adapters Troubleshooting Guide53-1001253-01Tuning network drivers4For the Brocade driver, you cannot directly configure the number of NetQu

Page 4

Brocade Adapters Troubleshooting Guide 8353-1001253-01AppendixAEvent Message ReferenceThis appendix provides details on event messages generated by ad

Page 5

84 Brocade Adapters Troubleshooting Guide53-1001253-01Event Message ReferenceANew virtual port created using proprietary interface: WWN = [logical por

Page 6

Brocade Adapters Troubleshooting Guide 8553-1001253-01Event Message ReferenceAVirtual port (WWN = [logical port WWN]) login failed. Max NPIV ports alr

Page 7

86 Brocade Adapters Troubleshooting Guide53-1001253-01Event Message ReferenceAIOC [IOC instance number] is disabledWarning Network and storage driver9

Page 8

Brocade Adapters Troubleshooting Guide 8753-1001253-01IndexAadapterdiagnostics, 62adapter BIOS not installed message, 22adapter event message files, 4

Page 9 - About this Document

88 Brocade Adapters Troubleshooting Guide53-1001253-01diagnosticsadapter, 62beaconing, 62enabling through BCU, 62enabling through HCM, 63echo testenab

Page 10 - Host operating system support

Brocade Adapters Troubleshooting Guide 8953-1001253-01HBA and CNA problemsproblemgeneral HBA and CNA, 8HBA memory test, 66HBA problemresolving BIOS bo

Page 11 - HBA support

90 Brocade Adapters Troubleshooting Guide53-1001253-01operating system support, x, xiiPPCI loopback tests, 65enabling through BCU, 65enabling through

Page 12 - What’s new in this document

Brocade Adapters Troubleshooting Guide 9153-1001253-01properties panel for HBA, 45publication references, 37QQoS performance issues, 16QoS settings, 7

Page 13 - Document conventions

Brocade Adapters Troubleshooting Guide xi53-1001253-01FCoE support• Windows Server 2003, version R2 with SP2• Windows Server 2008• Windows Server Core

Page 14 - Key terms

92 Brocade Adapters Troubleshooting Guide53-1001253-01temperature diagnostics, 66trace route, 67enable through HCM, 67enabling through BCU, 67troubles

Page 15 - Additional information

xii Brocade Adapters Troubleshooting Guide53-1001253-01• Although you can install an 8 Gbps SFP+ into a Brocade 415 or 425 HBA, only 4 Gbps maximum po

Page 16 - Providing details for support

Brocade Adapters Troubleshooting Guide xiii53-1001253-01Document conventionsThis section describes text formatting conventions and important notice fo

Page 17 - Command Function

xiv Brocade Adapters Troubleshooting Guide53-1001253-01Notes, cautions, and warningsThe following notices and statements are used in this manual. They

Page 18 - Document feedback

Brocade Adapters Troubleshooting Guide xv53-1001253-01Notice to the readerThis document may contain references to the trademarks of the following corp

Page 19 - In this chapter

xvi Brocade Adapters Troubleshooting Guide53-1001253-01Other industry resourcesFor additional resource information, visit the Technical Committee T11

Page 20 - Gathering problem information

Brocade Adapters Troubleshooting Guide xvii53-1001253-01• BCU adapter --list command.This command lists all adapters in the system and information suc

Page 21 - TABLE 1 Topology map details

xviii Brocade Adapters Troubleshooting Guide53-1001253-01• Enter the port --query <port_id> BCU command: Look for the FCoE MAC.The FCoE Forwarde

Page 22

Brocade Adapters Troubleshooting Guide 153-1001253-01Chapter1Introduction to troubleshootingIn this chapter•How to use this manual for troubleshooting

Page 23 - Isolating Problems

Copyright © 2009 Brocade Communications Systems, Inc. All Rights Reserved.Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, Ir

Page 24 - Isolate adapter problems

2 Brocade Adapters Troubleshooting Guide53-1001253-01Gathering problem information13. Use the BCU commands, HCM features, and host operating system co

Page 25

Brocade Adapters Troubleshooting Guide 353-1001253-01Gathering problem information1• Gather information for support:- Use appropriate tools on storage

Page 26 - General HBA and CNA problems

4 Brocade Adapters Troubleshooting Guide53-1001253-01Gathering problem information1

Page 27 - Port link is not active

Brsocade Adapters Troubleshooting Guide 553-1001253-01Chapter2Isolating ProblemsIn this chapter•How to use this chapter . . . . . . . . . . . . . . .

Page 28

6 Brsocade Adapters Troubleshooting Guide53-1001253-01How to use this chapter2“Failed to connect to agent on host... error when using HCM”“General HBA

Page 29

Brsocade Adapters Troubleshooting Guide 753-1001253-01How to use this chapter2“Network stack runs out of heap” “Ethernet network interface problems (C

Page 30 - • The agent is not running

8 Brsocade Adapters Troubleshooting Guide53-1001253-01General HBA and CNA problems2General HBA and CNA problemsThis section provides resolution for co

Page 31

Brsocade Adapters Troubleshooting Guide 953-1001253-01General HBA and CNA problems2Port link is not activeThe link between the adapter and switch port

Page 32

10 Brsocade Adapters Troubleshooting Guide53-1001253-01General HBA and CNA problems2Errors when installing brocade_driver_linux_<versions>.tar.g

Page 33 - BCU version mismatch warning

Brsocade Adapters Troubleshooting Guide 1153-1001253-01General HBA and CNA problems2c. Reseat SFPs in the adapter. Determine whether the installed SFP

Page 34 - HBA problems

Brocade Adapters Troubleshooting Guide iii53-1001253-01ContentsAbout this DocumentIn this chapter . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35 - UEFI boot problems

12 Brsocade Adapters Troubleshooting Guide53-1001253-01General HBA and CNA problems2Failed to connect to agent on host... error when using HCMAn “Adap

Page 36 - • Reseat the adapter

Brsocade Adapters Troubleshooting Guide 1353-1001253-01General HBA and CNA problems25. If HCM is still unable to connect to the HCM agent after using

Page 37 - BIOS boot problems

14 Brsocade Adapters Troubleshooting Guide53-1001253-01General HBA and CNA problems2NOTEYou can change the default communication port (34568) for the

Page 38 - Configuration menu

Brsocade Adapters Troubleshooting Guide 1553-1001253-01General HBA and CNA problems2Files needed for bfad.sys message appears If a “Files needed for b

Page 39

16 Brsocade Adapters Troubleshooting Guide53-1001253-01HBA problems2I/O data traffic issuesI/O data traffic issues are occurring, such as an applicati

Page 40 - • nm-tool

Brsocade Adapters Troubleshooting Guide 1753-1001253-01HBA problems21. Possible Cause: QoS is not enabled on both switch and adapter port.Action: Veri

Page 41

18 Brsocade Adapters Troubleshooting Guide53-1001253-01HBA problems2Boot devices not available in host’s Boot Manager menuFibre Channel attached boot

Page 42

Brsocade Adapters Troubleshooting Guide 1953-1001253-01HBA problems2 Drv[25] : Brocade Fibre Channel Adapter Bus Driver Drv[26] : SCSI Bus

Page 43

20 Brsocade Adapters Troubleshooting Guide53-1001253-01HBA problems24. Possible Cause: There is a problem with the remote port. Action: Verify that th

Page 44

Brsocade Adapters Troubleshooting Guide 2153-1001253-01HBA problems23. Possible Cause: The link between the adapter port and target is not active yet.

Page 45 - Poor network performance

iv Brocade Adapters Troubleshooting Guide53-1001253-01General HBA and CNA problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Adapter

Page 46

22 Brsocade Adapters Troubleshooting Guide53-1001253-01Ethernet network interface problems (CNA only)27. Press F10 to save the changes and exit the BI

Page 47

Brsocade Adapters Troubleshooting Guide 2353-1001253-01Ethernet network interface problems (CNA only)2To disable NetworkManager for SLES systems, perf

Page 48 - FCoE link is down

24 Brsocade Adapters Troubleshooting Guide53-1001253-01Ethernet network interface problems (CNA only)2Action: Check for other instances of this diagno

Page 49

Brsocade Adapters Troubleshooting Guide 2553-1001253-01Ethernet network interface problems (CNA only)26. Reboot the host system.Ping to remote server

Page 50 - CEE is not enabled

26 Brsocade Adapters Troubleshooting Guide53-1001253-01Ethernet network interface problems (CNA only)2VLAN creation and operation problemsVLAN creatio

Page 51 - Application Tool References

Brsocade Adapters Troubleshooting Guide 2753-1001253-01Ethernet network interface problems (CNA only)2Poor network performancePoor network performance

Page 52 - Information Chapter

28 Brsocade Adapters Troubleshooting Guide53-1001253-01FCoE and Fibre Channel problems2FCoE and Fibre Channel problemsThis section provides resolution

Page 53

Brsocade Adapters Troubleshooting Guide 2953-1001253-01FCoE and Fibre Channel problems2Disk I/O requests causes low throughput and high latency on Lin

Page 54

30 Brsocade Adapters Troubleshooting Guide53-1001253-01FCoE and Fibre Channel problems2Adapter not registering with the name server or cannot access s

Page 55

Brsocade Adapters Troubleshooting Guide 3153-1001253-01FCoE and Fibre Channel problems24. Possible Cause: The FC-MAP on the FCoE switch is not set for

Page 56

Brocade Adapters Troubleshooting Guide v53-1001253-01Adapter driver installation verification. . . . . . . . . . . . . . . . . . . . . . . . 34Confirm

Page 57 - Tools for Collecting Data

32 Brsocade Adapters Troubleshooting Guide53-1001253-01CEE network problems (CNA only)2CEE network problems (CNA only)This section provides informatio

Page 58 - Data to provide support

Brsocade Adapters Troubleshooting Guide 3353-1001253-01Verifying Fibre Channel and CEE links2NOTEAlso verify LED operation on a switch port that is co

Page 59

34 Brsocade Adapters Troubleshooting Guide53-1001253-01Adapter driver installation verification2Adapter driver installation verificationProblems with

Page 60 - Support Save

Brsocade Adapters Troubleshooting Guide 3553-1001253-01Adapter driver installation verification2Confirming driver package installation in Windows syst

Page 61

36 Brsocade Adapters Troubleshooting Guide53-1001253-01Adapter driver installation verification2• # dmesgThis command prints kernel boot messages. Ent

Page 62 - Support Save differences

Brsocade Adapters Troubleshooting Guide 3753-1001253-01Additional references for isolating problems2• cat /proc/vmware/versionThis displays the latest

Page 63 - • cfgShow

38 Brsocade Adapters Troubleshooting Guide53-1001253-01Additional references for isolating problems2

Page 64

Brocade Adapters Troubleshooting Guide 3953-1001253-01Chapter3Tools for Collecting DataIn this chapter•For detailed information . . . . . . . . . . .

Page 65 - Adapter event messages

40 Brocade Adapters Troubleshooting Guide53-1001253-01Data to provide support3Data to provide supportWhen problems occur requiring support assistance,

Page 66 - Host system logs

Brocade Adapters Troubleshooting Guide 4153-1001253-01Data collection using host system commands3Checking for Brocade network (BNA) driver modulelsmod

Page 67 - HCM logs

vi Brocade Adapters Troubleshooting Guide53-1001253-01Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 68 - Logging levels adjustment

42 Brocade Adapters Troubleshooting Guide53-1001253-01Data collection using BCU commands and HCM3Data collection using BCU commands and HCMYou can col

Page 69 - Port logging level

Brocade Adapters Troubleshooting Guide 4353-1001253-01Data collection using BCU commands and HCM3• Environment information• Data.xml file• Vital CPU,

Page 70 - Statistics

44 Brocade Adapters Troubleshooting Guide53-1001253-01Data collection using BCU commands and HCM3Initiating Support Save through the internet browserI

Page 71 - CEE query (CNA only)

Brocade Adapters Troubleshooting Guide 4553-1001253-01Data collection using Fabric OS commands3• The Converged Network Adapter (CNA) adapter Propertie

Page 72

46 Brocade Adapters Troubleshooting Guide53-1001253-01Data collection using Fabric OS commands3• fcpProbeShowUse this command to display the Fibre Cha

Page 73

Brocade Adapters Troubleshooting Guide 4753-1001253-01Adapter event messages3Adapter event messagesWhen applicable events occur during adapter operati

Page 74 - Fabric statistics

48 Brocade Adapters Troubleshooting Guide53-1001253-01Logs3NOTEComplete content for adapter driver event messages is included in Appendix A, “Event Me

Page 75 - IOC statistics

Brocade Adapters Troubleshooting Guide 4953-1001253-01Logs3Syslog supportYou can configure the HCM agent to forward events to a maximum of three syste

Page 76 - Logical port statistics

50 Brocade Adapters Troubleshooting Guide53-1001253-01Logs3- IP over FC - Events pertaining to IP over Fibre Channel.- VLAN - Events pertaining to a v

Page 77 - Remote port statistics

Brocade Adapters Troubleshooting Guide 5153-1001253-01Logs3Adjusting the adapter event logging levelSpecify the number of event messages logged by the

Page 78

Brocade Adapters Troubleshooting Guide vii53-1001253-01Appendix A Event Message ReferenceIndex

Page 79 - VLAN Statistics (CNA only)

52 Brocade Adapters Troubleshooting Guide53-1001253-01Statistics3Adjusting the Ethernet logging level through BCU Adjust port logging level for each E

Page 80 - Diagnostics

Brocade Adapters Troubleshooting Guide 5353-1001253-01Statistics3This section provides an overview of these statistics and how to access them. For mor

Page 81 - • External

54 Brocade Adapters Troubleshooting Guide53-1001253-01Statistics3• Transmitted broadcast octets• Transmitted broadcast frames• Transmitted broadcast V

Page 82

Brocade Adapters Troubleshooting Guide 5553-1001253-01Statistics3Displaying statistics through HCMTo display the Ethernet Statistics dialog box, use t

Page 83 - PCI loopback test

56 Brocade Adapters Troubleshooting Guide53-1001253-01Statistics3port_id Specifies the ID of the Ethernet port for which you will display the statist

Page 84 - Ping end points

Brocade Adapters Troubleshooting Guide 5753-1001253-01Statistics3IOC statistics Use BCU and HCM to display port-level statistics for the I/O controlle

Page 85 - Trace route

58 Brocade Adapters Troubleshooting Guide53-1001253-01Statistics3lpwwn Logical port world wide name. This is an optional argument. If the -l lpwwn arg

Page 86 - SCSI test

Brocade Adapters Troubleshooting Guide 5953-1001253-01Statistics3Displaying logical port statistics through BCUUse the lport --stats command to displa

Page 87 - Collecting SFP data

60 Brocade Adapters Troubleshooting Guide53-1001253-01Statistics3• Hardware abstraction layer (HAL) activityAs an example of using these statistics fo

Page 88 - Collecting port data

Brocade Adapters Troubleshooting Guide 6153-1001253-01Statistics3Virtual port statistics (HBA only)Use HCM and BCU to display logical port statistics

Page 89

viii Brocade Adapters Troubleshooting Guide53-1001253-01

Page 90

62 Brocade Adapters Troubleshooting Guide53-1001253-01Diagnostics3Displaying virtual port statistics through BCUUse the vlan --query command to displa

Page 91 - Authentication settings

Brocade Adapters Troubleshooting Guide 6353-1001253-01Diagnostics3fcdiag --linkbeacon <portid> {on | off} [<duration>]where:port_id ID of

Page 92

64 Brocade Adapters Troubleshooting Guide53-1001253-01Diagnostics3Performing loopback tests through HCMUse the Port Tests tab on the Diagnostics dialo

Page 93 - Persistent binding

Brocade Adapters Troubleshooting Guide 6553-1001253-01Diagnostics3-c frame count Specifies the frame count.-p pattern Specifies the pattern (must be

Page 94

66 Brocade Adapters Troubleshooting Guide53-1001253-01Diagnostics3Memory testUse the BCU or the HCM to perform a memory test for the adapter. NOTEPerf

Page 95 - Performance optimization

Brocade Adapters Troubleshooting Guide 6753-1001253-01Diagnostics3Issuing a ping command to end points through BCU Use the fcdiag --fcping BCU command

Page 96 - Windows tuning

68 Brocade Adapters Troubleshooting Guide53-1001253-01Diagnostics34. Select FC Trace Route.5. Select the adapter port and target for which you wish to

Page 97 - Tuning network drivers

Brocade Adapters Troubleshooting Guide 6953-1001253-01Collecting LLDP data (CNA only)3lpwwn Logical port WWN. 0 indicates the base port; otherwise.Tes

Page 98 - Linux tuning

70 Brocade Adapters Troubleshooting Guide53-1001253-01Collecting port data33. Click the SFP tab in the right pane.Port power on management Use the Por

Page 99 - VMware tuning

Brocade Adapters Troubleshooting Guide 7153-1001253-01Collecting port data3• Operating speed• Receive and transmit BB credit• Frame data field size• M

Page 100 - 53-1001253-01

Brocade Adapters Troubleshooting Guide ix53-1001253-01About this DocumentIn this chapter•Supported CNA hardware and software . . . . . . . . . . . .

Page 101 - Event Message Reference

72 Brocade Adapters Troubleshooting Guide53-1001253-01Collecting port data3• Maximum transmission unit (MTU)• Target rate limiting (TRL) enabled or di

Page 102 - TABLE 9 Driver event messages

Brocade Adapters Troubleshooting Guide 7353-1001253-01Authentication settings3Displaying the port logUse the HCM debug --portlog BCU command to displa

Page 103

74 Brocade Adapters Troubleshooting Guide53-1001253-01QoS and target rate limiting settings (HBA only)31. Select a port from the device tree.2. Select

Page 104

Brocade Adapters Troubleshooting Guide 7553-1001253-01Persistent binding3where:port_id Specifies the ID of the port for which you want to query attrib

Page 105

76 Brocade Adapters Troubleshooting Guide53-1001253-01Persistent binding33. Select Configure > Persistent Binding.ORRight-click on an adapter or po

Page 106

Brocade Adapters Troubleshooting Guide 7753-1001253-01Chapter4Performance optimizationIn this chapter•Tuning storage drivers . . . . . . . . . . . . .

Page 107

78 Brocade Adapters Troubleshooting Guide53-1001253-01Tuning storage drivers4Solaris tuningTo increase I/O transfer performance, set the following par

Page 108

Brocade Adapters Troubleshooting Guide 7953-1001253-01Tuning network drivers4MSI-X is supported in Windows Vista and Windows Server 2008. To enable MS

Page 109

80 Brocade Adapters Troubleshooting Guide53-1001253-01Tuning network drivers4Linux tuningAll Linux tunable parameters for the network driver are optim

Page 110

Brocade Adapters Troubleshooting Guide 8153-1001253-01Tuning network drivers4VMware tuningAll VMware tunable parameters for the network driver are opt