When running with 16:1 oversubscription ratio on a VC-FC module, the hardware registers do not
allow auto-routed traffic for the sixteenth server blade. When this scenario occurs, the firmware
routes FC frames, causing a significant drop in the performance.
The following issues that existed in Virtual Connect 1.15b and earlier versions have been resolved in
Virtual Connect 1.16:
Server profiles could be assigned to a bay occupied by a non-server device.
The Virtual Connect GUI labeled all server bays as Bay 0 and failed to recognize any servers in the
enclosure.
Signal quality for 10GBASE-CX4 cables was poor.