GSS CCT Evaluation Technical Report Page 42 of 53
© 2014 Gossamer Security Solutions, Inc.
Document: AAR-BrocadeFastIron8010
All rights reserved.
The Brocade products do not have an update available for testing. Brocade typically does not release small
updates or patches. Instead, new firmware versions are released. In order to perform this test, evaluator had to
roll back to an engineering version and then roll forward to the released product. The version did update properly.
For the improper update, the evaluator attempted to load an image that did not match the signature. The
signature verification failed.
2.7 TOE ACCESS (FTA)
2.7.1 TSF-INITIATED TERMINATION (FTA_SSL.3)
2.7.1.1 FTA_SSL.3.1
TSS Assurance Activities: None Defined
Guidance Assurance Activities: None Defined
Testing Assurance Activities: The evaluator shall perform the following test:
Test 1: The evaluator follows the operational guidance to configure several different values for the inactivity time
period referenced in the component. For each period configured, the evaluator establishes a remote interactive
session with the TOE. The evaluator then observes that the session is terminated after the configured time period.
The evaluator set the SSH time period to 2 minutes and observed a SSH timeout. The evaluator then set the SSH
timeout to 3 minutes and observed a SSH timeout. Note that when the session terminated, the screen was left as-
is and a new login prompt was presented.
2.7.2 USER-INITIATED TERMINATION (FTA_SSL.4)
2.7.2.1 FTA_SSL.4.1
TSS Assurance Activities: None Defined