GSS CCT Evaluation Technical Report Page 41 of 56 © 2015 Gossamer Security Solutions, Inc.
Document: AAR-BrocadeNetIron5.8 All rights reserved.
The evaluator set the local clock from the console and observed the time change. The evaluator then configured a
NTP server and had the appliance connect to the NTP server and update the time. The evaluator observed the time
update from the NTP server.
2.6.4 TSF TESTING (FPT_TST_EXT.1)
2.6.4.1 FPT_TST_EXT.1.1
TSS Assurance Activities: The evaluator shall examine the TSS to ensure that it details the self tests that are run by
the TSF on start-up; this description should include an outline of what the tests are actually doing (e.g., rather than
saying 'memory is tested', a description similar to 'memory is tested by writing a value to each memory location
and reading it back to ensure it is identical to what was written' shall be used). The evaluator shall ensure that the
TSS makes an argument that the tests are sufficient to demonstrate that the TSF is operating correctly.
Section 6.6 provides a discussion of the self-tests. The self-tests include basic read-write memory, flash read,
software checksum tests, and device detection tests. Additionally, the TOE is designed to query each pluggable
module which in turn includes its own diagnostics that will serve to help identify any failing modules.
Guidance Assurance Activities: The evaluator shall also ensure that the operational guidance describes the
possible errors that may result from such tests, and actions the administrator should take in response; these
possible errors shall correspond to those described in the TSS.
In the Reloading the device section of the FIPS Guide, there is a discussion of the FIPS self-tests. This discussion
also the possible errors that may arise such as:
Crypto module initialization and KNown Answer Test (KAT) failed with reason:(Error
Code 0x80000000)’CKR_VENDOR_DEFINED’
FIPS: MP Primary image verification failed
FIPS: MP Secondary image verification failed
FIPS: MP Monitor image verification failed
The Hardware Installation Guides for each model provides a Table 4 which contains all of the LEDs on the appliance
and explains what each indicator means depending on its color. For example, if the PS1 LED is yellow, the power
supply is not functioning properly.
The TSS description about the self-tests focuses on the FIPS self-tests. As such, the discussion in the FIPS Guide
discusses the possible errors that may arise and how to possibly address some of the errors
Testing Assurance Activities: None Defined