Page view 207
190 Fabric OS Encryption Administrator’s Guide (DPM)
53-1002720-02
SRDF/TF/RP manual rekeying procedures
3
5. Wait until the rekey operation on the source LUN has completed. If the source LUN has a
rekeying error of any type, the TF source/target LUN pair should not be
established/synchronized. The source LUN rekey must complete successfully before the
source/target pair is re-established.
6. Remove target LUN access by using one of the following procedures:
Ensure that no hosts read or write information to the TF target LUNs, or
Make the target LUN not ready to the host by using the -not_ready option of TF
clone/snap when activating the target device.
7. Start TimeFinder pair synchronization so the rekeyed data from the source LUN is copied to
target LUN.
8. Verify that the TimeFinder pair is synchronized.
9. If you want to bring the target LUN online for host access, once the TimeFinder pair has been
synchronized, perform the following command on every path/container that has access to the
target device:
FabricAdmin:switch> cryptocfg --refreshDEK <target_container> <target LUN ID>
<initiator PWWN>
NOTE
The refreshDEK command forces the Brocade Encryption Switch to re-read the metadata on
the target LUN, and then updates the FPGA tables for the LUN if the DEK in the metadata has
changed. It is therefore imperative that this command be run after every rekeying operation
that is completed for TF target devices.
Rekeying local site (R1) SRDF LUNs
Manual rekeying is supported for SRDF R1 LUNs. If it is required to rekey the R2 LUN, SRDF role
reversal/swap is necessary. This procedure is covered in “Rekeying remote site (R2) SRDF LUNs”.
1. Log in as Admin or FabricAdmin.
2. Split the SRDF R1/R2 LUN pair ensuring that the data replication from the source R1 LUN to
the destination R2 LUN has been stopped.
NOTE
During all rekeying operations, data replication between the source and target LUN must be
stopped.
3. During the rekeying operation, if desired, you can enable the remote target ports so the target
LUNs can be accessed by the remote hosts in read-only mode.
4. Issue a manual rekey request for the source LUN.
FabricAdmin:switch> cryptocfg --manual_rekey <R1 source container> <R1 source
LUN ID> <initiator PWWN>
5. Wait until the rekey operation on the source LUN has completed. If the source LUN has a
rekeying error of any type, the SRDF pair should not be established/synchronized. The source
LUN rekey must complete successfully before the source/target pair is re-established.