Page view 181
160 Web Tools Administrator’s Guide
Publication Number: 53-1000435-01
Configuring Fabric Watch thresholds
12
To configure threshold traits
1. Open Fabric Watch window.
2. Click the Threshold Configuration tab.
FIGURE 73 Threshold configuration in Fabric Watch
3. Click the Trait Configuration subtab.
4. In Fabric Watch Explorer, click a class.
5. Under Area Selection, choose an area from drop-down list.
This sets the units in the Units field.
The module displays two columns of trait information, labeled System Default and Custom
Defined. You cannot modify the information in the System Default column.
6. In the Activate Level area:
- Click the System Default radio button to use the system default settings and proceed to
step 11.
or
- Click the Custom Defined radio button to specify new settings and proceed to the next
step.
7. If necessary, select a time to record the event in the Time Base field.
8. Type the lowest boundary of the normal zone in the Low Boundary field.
9. Type the highest boundary of the normal zone in the High Boundary field.