Web Tools Administrator’s Guide 163
Publication Number: 53-1000435-01
Displaying Fabric Watch alarm information
12
Displaying Fabric Watch alarm information
From Fabric Watch, you can view two types of reports:
Alarm notifications—Displays the alarms that have occurred for a selected class/area
Alarm configuration—Displays threshold and alarm configurations for a selected class/area
DISPLAYING AN ALARM CONFIGURATION REPORT
Use the Threshold Configuration tab, Configuration Report subtab to display a report of the
configuration for a selected class/area with the following information:
Threshold settings (labeled Threshold Configuration)
Notification settings (labeled Action Configuration)
Element settings (not labeled)
You can scroll through this information but cannot make changes.
To view an alarm configuration report
1. Open the Fabric Watch window.
2. Click the Threshold Configuration tab.
3. Click a previously configured element from Fabric Watch Explorer (see “Enabling or disabling
threshold alarms for individual elements” on page 161).
4. Under Area Selection, click the alarm area report to be viewed.
5. Click the Configuration Report subtab.
This tab displays a report of the configuration for the selected area.
DISPLAYING ALARMS
Using the Alarm Notification tab, you can view a list of all alarms that have occurred for a selected
class/area (see Figure 72 on page 158). Table 9 describes the columns in this report. You can click
the header of each column to change the way the information is sorted in your view. You can also
right-click the column header and choose sort options from a menu.
NOTE
Note that for the FRU class, only the Name, State, and Time columns are displayed. In addition, if
the FRU area is Fan, the Name column refers to either a fan or a fan FRU, depending on the switch
model. See “Displaying detailed fan hardware status” on page 150 for more information.)
TABLE 9 Alarm notification table fields
Field Description
Name The string assigned to the element that had an event
State The current state of the element
Reason The event type that was triggered
Last Value The data value of the element when the event was triggered
Current Value The current data value of the element
Time Time when the event occurred