Brocade Communications Systems 4900 Service Manual Page 173

  • Download
  • Add to my manuals
  • Print
  • Page
    / 266
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 172
Web Tools Administrator’s Guide 151
Publication Number: 53-1000435-01
Displaying switch information
11
For Brocade 24000 and 48000 directors and Brocade 4100, 4900, 5000, and 7500 switches,
the Fan No. column indicates the fan FRU number.
For Brocade 3900, the Fan No. column indicates the fan number.
The Brocade 200E, 3250, 3850 4012, 4016, 4018, 4020, and 4024 switches do not contain
fan FRUs, so for these switch models, the Fan No. column indicates the fan number.
NOTE
For these switches, if the Fan Status window has no “Fan Speed” column, the speed is not
monitored.
To display the fan status detail
1. Select a switch from the Fabric Tree.
The selected switch appears in the Switch View. The icon on the Fan button indicates the
overall status of the fan.
2. Click the Fan button.
The detailed fan status for the switch is displayed, as shown in Figure 65.
DISPLAYING THE TEMPERATURE STATUS
The icon on the Temp button indicates the overall status of the temperature. For more information
regarding switch temperature, refer to the appropriate hardware documentation.
To display the temperature status detail
1. Select a switch from the Fabric Tree.
The selected switch appears in the Switch View. The icon on the Temp button indicates the
overall status of the temperature.
2. Click the Temp button on the Switch View.
The detailed temperature sensor states for the switch are displayed, as shown in Figure 66.
FIGURE 66 Temperature Sensor States window
DISPLAYING THE POWER SUPPLY STATUS
The icon on the Power button indicates the overall status of the power supply status. For more
information regarding switch power modules, refer to the appropriate hardware documentation.