Brocade 6510 Switch Technical Specifications
This document highlights the features and specifications for the Brocade 6510 switch.
System specifications
System component Description
Enclosure 1U, non-port side front-to-back exhaust airflow, power from back
Power inlet C14
Power supplies Dual, hot-swappable redundant power supplies with integrated system cooling fans
Fans Two fans per FRU
Cooling Port side to the non-port side of the switch (non-port side exhaust) and non-port side
to the port side (port side exhaust)
System architecture Nonblocking shared memory switch
System processors PowerPC 440EPx @ 667 MHz
Port-to-port latency <700 nanoseconds with no contention (destination port is free)
Fibre Channel
System component Description
Fibre Channel ports SFP+ optical transceivers that support any combination of Short Wavelength (SWL)
and Long Wavelength (LWL) or Extended Long Wavelength (ELWL) optical media
among the switch ports.
Capable of operating at 2, 4, 8, or 16 Gbps depending on SFP+ models and able to
auto-negotiate to the maximum link speed.
2, 4, and 8 Gbps performance is enabled by 8 Gbps SFP+ transceivers.
4, 8, and 16 Gbps performance is enabled by 16 Gbps SFP+ transceivers.
ANSI Fibre Channel
protocol
FC-PH (Fibre Channel Physical and Signaling Interface standard)
Modes of operation Fibre Channel Class 2 and Class 3
Fabric initialization Complies with FC-SW-3 Rev. 6.6