Verifying proper operation
To verify the proper operation of the power supply after power on, you can observe the LEDs on the
power supply.
After the Brocade device powers on, you can observe the LEDs on the front of the device to verify that
it initialized successfully. There is a single LED on the power supply which should be steady green
when the power supply is receiving power and under normal operation.Table 1 outlines the LEDs, the
desired state of each LED, possible abnormal states of each LED, and what to do if an LED indicates
an abnormal state.
To verify proper operation, complete the following steps.
1. Verify that the power supply's LED is steady green on the back of the device.
2. Verify that the power supply was placed in power supply bay #1 and operational by observing a
steady green LED lighting up "P1" on the front of the device.
LEDs for power and fans (located on front of device )TABLE 19
LED State Meaning
Fan (labeled Fn) On The fan tray is powered on and is operating normal.
Off The fan tray is not powered on, or has been removed.
PS1 (labeled P1) Off Power supply 1 is not installed or is not providing power.
Amber Power supply 1 is installed, but not connected or a fault is detected.
Green Steady Power supply 1 is installed and is functioning normally.
Green Blinking Power supply 1 has input power, but is not enabled and has no output
power.
PS2 (labeled P2) Off Power supply 2 is not installed or is not providing power.
Amber Power supply 2 is installed, but not connected or a fault is detected.
Green Steady Power supply 2 is installed and is functioning normally.
Green Blinking Power supply 2 has input power, but is not enabled and has no output
power.
The LEDs for Fan, PS1 and PS2 are located on the right side of the front panel for Brocade NetIron
CES Series and Brocade NetIron CER Series 2024 models (On the Brocade NetIron CES Series
2048 and Brocade NetIron CER Series 2048 models, these LEDs are located on the left side of the
front panel).
The software regularly polls the hardware for power status information. You can display the status
information from any management session. In addition, the software automatically generates a
Syslog message and SNMP trap if a status change occurs.
Displaying the status of the power supplies
You can display the status of the power supplies by entering the show chassis command at any level
of the CLI. The display shows whether a power supply is installed in the specified power supply slot
Verifying proper operation
92 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide