Brocade Communications Systems VDX 8770-8 Installation Guide Page 76

  • Download
  • Add to my manuals
  • Print
  • Page
    / 116
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 75
FIGURE 22 Removal and replacement of the management module
Replacing a management module
Refer to ESD precautions on page 69 before replacing a management module.
Complete the following steps to insert an management module. Refer to the illustration provided in
Removing a management module on page 75.
1. Unpack the new management module and remove it from the anti-static bag.
2. Inspect the module for damage.
3. Remove the protective caps from the backplane connectors.
4. Rotate the ejectors toward the center of the module.
5. Align the module pan with the guides in the slot. The first management module should be installed
in slot M1.
6. Slide the management module into the slot until it is firmly seated.
7. Rotate the ejectors away from the center of the module face until the module is tight in the slot.
8. Tighten the captive screws using the Phillips screwdriver. Verify that the power LED is green. If not,
ensure that the management module has power and is firmly seated and that the ejectors are in the
locked position.
9. Reconnect any cables that were attached to the old module.
Replacing a management module
76 Brocade VDX 8770-8 Hardware Installation Guide