Brocade Communications Systems Brocade Superx Series Installation Guide Page 100

  • Download
  • Add to my manuals
  • Print
  • Page
    / 188
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 99
88 Brocade FastIron SX Series Chassis Hardware Installation Guide
53-1002500-01
Managing the cooling system
4
The temperature of the fan control modules
The status and speed of the fans
The temperature warnings sent to the system log
Displaying the temperature
By default, the Brocade device polls the temperature sensor on each module every 60 seconds to
get the temperature of each module. The Brocade device records the highest temperature reading
of the modules in each thermal plane.
The show chassis command displays the temperature reading of each thermal plane, as shown in
the following examples.
This following shows an example output.
The following shows an example output on the FSX 800. The output is similar on the FSX 1600.
Syntax: show chassis
Displaying fan status and speed
The show chassis command displays the status and speed of the fans in the Brocade chassis. The
following shows an example output.
Syntax: show chassis
For each fan, the display shows the following information.
Brocade# show chassis
...
Fan controlled temperature:
Rule 1/2 (MGMT CARDS THERMAL PLANE): 53.0 deg-C...
Rule 2/2 (LINE CARDS THERMAL PLANE): 59.0 deg-C...
...
Brocade# show chassis
...
Fan controlled temperature:
Rule 1/3 (MGMT CARDS THERMAL PLANE): 55.5 deg-C...
Rule 2/3 (LINE CARDS THERMAL PLANE): 59.6 deg-C...
Rule 3/3 (SWITCH FABRIC CARDS THERMAL PLANE): 78.7 deg-C...
...
Brocade# show chassis
...
Fan 1 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 2 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 3 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 4 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 5 ok, speed (auto): 1<->[[2]]<->3<->4
Fan 6 ok, speed (auto): 1<->[[2]]<->3<->4
...
Page view 99