Page view 76
Switch fabric module removal and replacement
The Brocade VDX 8770-8 has up to six Switch fabric modules (SFMs). The modules can be installed
only in slots S1 through S6. There must be at least one switch fabric module installed in either slot S3 or
slot S4.
1 Ejectors
2 Captive screws
3 Status LED
4 Power LED
5 Slider
6 Power enable pin
7 Slider screws
FIGURE 23 Switch Fabric Module front view
Time and items required
The replacement procedure for the switch fabric module takes approximately 10 minutes. The following
items are required for the switch fabric module replacement:
ESD grounding strap
#2 Phillips screwdriver
Replacement switch fabric module
Removing a switch fabric module
You can continue to operate the device while a switch fabric module is being replaced.
Switch fabric module removal and replacement