NOTE
To insure adequate bonding when attaching the provided Panduit LCD6-10AF two-hole ground lug, a
minimum of 20 inch pounds of torque is required to be applied to the mounting hardware used to
attach the ground lug. Use a star washer to ensure an NEBS compliant connection.
Device installation
You can install devices on a desktop, or in an equipment rack.
Installing the device on a desktop
Follow the steps for desktop installation.
1. Set the device on a flat desktop, table, or shelf. Make sure that adequate ventilation is provided for
the system - a 3-inch clearance is recommended on each side.
2. Go to System power on page 59.
Installing the device in a rack
<<This section is also in the FGS HW Install Guide. Any changes here should also be made there.>>
For rack mount installation, Brocade recommends that you use the rack mount ears attached to the unit.
Each unit ships with rack ears attached to the front of the unit. You can mount the rack ears in 4
different locations on the device.
NOTE
While attaching the chassis to the rack, star washers shall be used to provide better grounding of the
chassis to the rack. Additionally if any single hole grounding lugs are used star washers shall be used
as a means to prevent rotation of the lug.
Forward rack mount position
The Brocade devices ship with the rack ears attached to the front of the device as shown below.
Device installation
Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 55
53-1003263-02