CAUTION
Ensure that the device does not overload the power circuits, wiring, and over-current
protection. To determine the possibility of overloading the supply circuits, add the ampere
(amp) ratings of all devices installed on the same circuit as the device. Compare this total with
the rating limit for the circuit. The maximum ampere ratings are usually printed on the devices
near the input power connectors.
CAUTION
Carefully follow the mechanical guides on each side of the power supply slot and make sure
the power supply is properly inserted in the guides. Never insert the power supply upside
down.
NOTE
Power supplies are hot swappable.
CAUTION
Remove the power cord from a power supply before you install it in or remove it from the
device. Otherwise, the power supply or the device could be damaged as a result. (The device
can be running while a power supply is being installed or removed, but the power supply itself
should not be connected to a power source.)
CAUTION
The power supply is designed exclusively for use with the Brocade NetIron CES Series and
Brocade NetIron CER Series devices. The power supply produces extensive power. Installing
the power supply in a device other than a NetIron CES Series or NetIron CER Series will cause
damage to your equipment.
DANGER
Disconnect the power cord from all power sources to completely remove power from the
device.
DANGER
Make sure to choose the appropriate circuit device depending on the number of AC power
supplies installed in the chassis. The minimum current draw for the system is one AC power
supply.
DANGER
Make sure that the power source circuits are properly grounded, then use the power cord
supplied with the device to connect it to the power source.
DANGER
If the installation requires a different power cord than the one supplied with the device, make
sure you use a power cord displaying the mark of the safety agency that defines the
regulations for power cords in your country. The mark is your assurance that the power cord
can be used safely with the device.